Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 222. Chassis LED Control Settings Unique
Name
chassisLEDControlSettingsUnique
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.25
Description Defines the readings and settings of the LED control hardware in the chassis.
Syntax DellLEDControlSettings (See Front-Panel LED Control Settings)
Access Read-only
Table 223. Chassis Hard-Drive (HD) Fault Clear Control Capabilities
Name
chassisHDFaultClearControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.26
Description Specifies whether the chassis allows reset of the chassis hard-drive fault LED.
Syntax DellHDFaultLEDControlCapabilities (See Hard-Drive Fault LED Control Capabilities )
Access Read-only
Table 224. Chassis HD Fault Clear Control Settings
Name
chassisHDFaultClearControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.27
Description Allows reset of the chassis hard-drive fault LED.
Syntax DellHDFaultLEDControlSettings (See Hard-Drive Fault LED Control Settings)
Access Read-only
Table 225. Chassis Identify Flash Control Capabilities
Name
chassisIdentifyFlashControlCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.28
Description Specifies whether the chassis front-panel LED can be set to flash.
Syntax DellChassisIdentifyControlCapabilities (See Chassis Identification Control Capabilities)
Access Read-only
Table 226. Chassis Identify Flash Control Settings
Name
chassisIdentifyFlashControlSettings
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.29
Description Causes the chassis front-panel LED to flash.
Syntax DellChassisIdentifyControlSettings (See Chassis Identification Control Capabilities)
Access Read-only
Table 227. Chassis Lock Present
Name
chassisLockPresent
Object ID 1.3.6.1.4.1.674.10892.1.300.10.1.30
Description Specifies whether a chassis lock is present on the chassis.
Syntax DellBoolean
Access Read-only
60 Server Administrator Group