Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 174. System State AC Power Cord Status Combined (continued)
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.36
Description Defines the overall status of all AC power cords for any AC power switches in this
chassis.
Syntax DellStatus
Access Read-only
Table 175. System State AC Power Cord Status Details
Name
systemStateACPowerCordStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.37
Description Defines the individual status of all AC power cords for any AC power switches in this
chassis. The first byte returned represents the status of the first AC power cord, the
second byte returned represents the status of the second AC power cord, and so on.
Syntax Octet String
Access Read-only
Table 176. System State Redundant Memory Unit State Details
Name
systemStateRedundantMemoryUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.38
Description Defines the state of all redundant memory units in this chassis. The results are returned
as a binary octet string, each byte of the octet string represents the state of the
specific object. The first byte returned represents the state of the first object, and so
on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 177. System State Redundant Memory Unit Status Redundancy
Name
systemStateRedundantMemoryUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.39
Description Defines the overall redundancy status for redundant memory.
Syntax DellStatusRedundancy
Access Read-only
Table 178. System State Redundant Memory Unit Status Details
Name
systemStateRedundantMemoryUnitStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.40
Description Defines the status of all redundant memory units in this chassis. The results are
returned as a binary octet string, each byte of the octet string represents the status of
the specific object. The first byte returned represents the status of the first object, and
so on. The bytes have the same definition type as DellStatusRedundancy.
Syntax Octet String
Access Read-only
Table 179. System State Event Log Status
Name
systemStateEventLogStatus
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.41
Server Administrator Group 51