Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 159. System State Cooling Device Status Combined (continued)
Access Read-only
Table 160. System State Cooling Device Status Details
Name
systemStateCoolingDeviceStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.22
Description Defines the status of all cooling devices in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the status of a specific
cooling device. The first byte returned represents the status of the first cooling device,
the second byte returned represents the status of the second cooling device, and so on.
The bytes have the same definition type as DellStatus.
Syntax Octet String
Access Read-only
Table 161. System State Temperature State Details
Name
systemStateTemperatureStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.23
Description Defines the state of all temperature probes in this chassis. The results are returned as
a binary octet string. Each byte of the octet string represents the state of a specific
temperature probe. The first byte returned represents the state of the first temperature
probe, the second byte returned represents the status of the second temperature
probe, and so on. The bytes have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 162. System State Temperature Status Combined
Name
systemStateTemperatureStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.24
Description Defines the status of all temperature probes in this chassis. The result is returned as a
combined status value. The value has the same definition type as DellStatus.
Syntax DellStatus
Access Read-only
Table 163. System State Temperature Status Details
Name
systemStateTemperatureStatusDetailsly
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.25
Description Defines the status of all temperature probes in this chassis. The first byte returned
represents the status of the first temperature probe, the second byte returned
represents the status of the second temperature probe, and so on.
Syntax Octet String
Access Read-only
Table 164. System State Memory Device State Details
Name
systemStateMemoryDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.26
Description Defines the state of all memory devices in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of the specific
48 Server Administrator Group