Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 155. System State Cooling Unit State Details
Name
statesystemStateCoolingUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17
Description Defines the state of all cooling units in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of a specific cooling
unit. The first byte returned represents the state of the first cooling unit, the second
byte returned represents the state of the second cooling unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 156. System State Cooling Unit Status Redundancy
Name
systemStateCoolingUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18
Description Defines the state of all cooling units in this chassis.
Syntax DellStatusRedundancy
Access Read-only
Table 157. System State Cooling Unit State Details
Name
systemStateCoolingUnitstateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19
Description Defines the state of all cooling units in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of a specific cooling
unit. The first byte returned represents the state of the first cooling unit, the second
byte returned represents the state of the second cooling unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 158. System State Cooling Device State Details
Name
systemStateCoolingDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20
Description Defines the state of all cooling devices in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific
cooling device. The first byte returned represents the state of the first cooling device,
the second byte returned represents the state of the second cooling device, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 159. System State Cooling Device Status Combined
Name
systemStateCoolingDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21
Description This attribute defines the cooling device status of all cooling devices in this chassis. The
results is returned as a combined status value. The value has the same definition type as
DellStatus.
Syntax DellStatus
Server Administrator Group 47