Table 155. System State Cooling Unit State Details
Name
statesystemStateCoolingUnitStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.17
Description Defines the state of all cooling units in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of a specific cooling
unit. The first byte returned represents the state of the first cooling unit, the second
byte returned represents the state of the second cooling unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 156. System State Cooling Unit Status Redundancy
Name
systemStateCoolingUnitStatusRedundancy
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.18
Description Defines the state of all cooling units in this chassis.
Syntax DellStatusRedundancy
Access Read-only
Table 157. System State Cooling Unit State Details
Name
systemStateCoolingUnitstateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.19
Description Defines the state of all cooling units in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of a specific cooling
unit. The first byte returned represents the state of the first cooling unit, the second
byte returned represents the state of the second cooling unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 158. System State Cooling Device State Details
Name
systemStateCoolingDeviceStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.20
Description Defines the state of all cooling devices in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific
cooling device. The first byte returned represents the state of the first cooling device,
the second byte returned represents the state of the second cooling device, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 159. System State Cooling Device Status Combined
Name
systemStateCoolingDeviceStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.21
Description This attribute defines the cooling device status of all cooling devices in this chassis. The
results is returned as a combined status value. The value has the same definition type as
DellStatus.
Syntax DellStatus
Server Administrator Group 47