Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 145. System State Power Unit Status Details (continued)
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.7
Description Defines the status of all power units in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the status of a specific power
unit. The first byte returned represents the status of the first power unit, the second
byte returned represents the status of the second power unit, and so on. The bytes
have the same definition type as DellStatusRedundancy.
Syntax Octet String
Access Read-only
Table 146. System State Power Supply State Details
Name
systemStatePowerSupplyStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.8
Description Defines the state of all power supplies in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the state of a specific
power supply. The first byte returned represents the state of the first power supply, the
second byte returned represents the state of the second power supply, and so on. The
bytes have the same definition type as DellStateSettings.
Syntax Octet String
Access Read-only
Table 147. System State Power Supply Status Combined
Name
systemStatePowerSupplyStatusCombined
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.9
Description Defines the status of all power supplies in this chassis.
Syntax DellStatus
Access Read-only
Table 148. System State Power Supply Status Details
Name
systemStatePowerSupplyStatusDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.10
Description Defines the status of all power supplies in this chassis. The results are returned as a
binary octet string, Each byte of the octet string represents the status of a specific
power supply. The first byte returned represents the status of the first power supply,
the second byte returned represents the status of the second power supply, and so on.
The bytes have the same definition type as DellStatus.
Syntax Octet String (Size (1..128))
Access Read-only
Table 149. System State Voltage State Details
Name
systemStateVoltageStateDetails
Object ID 1.3.6.1.4.1.674.10892.1.200.10.1.11
Description Defines the state of all voltage probes in this chassis. The results are returned as a
binary octet string. Each byte of the octet string represents the status of a specific
voltage probe. The first byte returned represents the status of the first voltage probe,
the second byte returned represents the status of the second voltage probe, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax Octet String
Server Administrator Group 45