Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1876. Virtual Disk Write Policy (continued)
Possible values:
1: Enabled - Adaptec Write Cache Enabled Protected
2: Disabled - Adaptec Write Cache Disabled
3: LSI Write Back
4: LSI Write Through
5: Enabled Always (Adaptec only)
6: Enabled Always (SAS only)
9: Not Applicable
Syntax INTEGER
Access Read-only
Table 1877. Virtual Disk Read Policy
Name
virtualDiskReadPolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.11
Description Indicates whether the controller's read cache are used when reading from a virtual disk.
Possible values:
1: Enabled - Adaptec Read Cache Enabled
2: Disabled - Adaptec Read Cache Disabled
3: LSI Read Ahead
4: LSI Adaptive Read Ahead
5: LSI No Read Ahead
9: Not Applicable
Syntax INTEGER
Access Read-only
Table 1878. Virtual Disk Cache Policy
Name
virtualDiskCachePolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.12
Description Indicates whether the controller's cache is used when reading from or writing to a
virtual disk. Possible values: 1: Direct I/O (LSI) 2: Cached I/O (LSI) 99: Not Applicable
Syntax INTEGER
Access Read-only
Table 1879. Virtual Disk Layout
Name
virtualDiskLayout
Object ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.13
Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3:
RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAID-50 19: Concatenated RAID 1 24:
RAID-60 25: CacheCade
Syntax INTEGER
Access Read-only
414 Storage Management Group