Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1852. NVME Adapter Length In Mega Bytes (continued)
Description Size in megabytes of the NVMe Adapter.
Syntax INTEGER
Access Read-only
Table 1853. NVME Adapter Length Offset Bytes
Name
nvmeAdapterLengthOffsetBytes
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.18
Description Number of bytes after total number of megabytes have been subtracted from the total
size of the NVMe Adapter.
Syntax INTEGER
Access Read-only
Table 1854. NVME Adapter Device ID
Name
nvmeAdapterDeviceID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.19
Description The device Id of the NVMe Adapter.
Syntax INTEGER
Access Read-only
Table 1855. NVME Adapter Model Number
Name
nvmeAdapterModelNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.20
Description Model number of the NVMe Adapter as per the manufacturer.
Syntax DisplayString
Access Read-only
Table 1856. NVME Adapter Negotiated Speed
Name
nvmeAdapterNegotiatedSpeed
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.21
Description The negotiated speed of the NVMe adapter in GT/s.
Syntax DisplayString
Access Read-only
Table 1857. NVME Adapter Capable Speed
Name
nvmeAdapterCapableSpeed
Object ID 1.3.6.1.4.1.674.10893.1.20.130.18.1.22
Description The maximum rated speed of the NVMe adapter in GT/s.
Syntax INTEGER
Access Read-only
Table 1858. NVME Adapter Remaining Rated Write Endurance
Name
nvmeAdapterRemainingRatedWrEnd
Storage Management Group 409