Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1811. Battery Predicted Capacity (continued)
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge capacity of the
battery cannot be determined until the Learn cycle is complete.
Syntax Integer
Access Read-only
Table 1812. Battery Next Learn Time
Name
batteryNextLearnTime
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description Indicates the time (in hours) the next learn cycle must be executed
Syntax Integer
Access Read-only
Table 1813. Battery Learn State
Name
batteryLearnState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.12
Description Specifies the learn state activity of the battery.
Possible values:
1: Failed
2: Active
4: Timed out
8: Requested
16: Idle
32: due
Syntax Integer
Access Read-only
Table 1814. Battery ID
Name
batteryID
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.13
Description Represents unique id for battery.
Syntax Integer
Access Read-only
Table 1815. Battery Maximum Learn Delay
Name
batteryMaxLearnDelay
Object ID 1.3.6.1.4.1.674.10893.1.20.130.15.1.14
Description The maximum amount of time (in hours) that the battery learn cycle can be delayed.
Storage Management Group 401