Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1745. Power Supply NexusID (continued)
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.10
Description Durable unique ID for this power supply.
Syntax DisplayString
Access Read-only
Table 1746. Power Supply Revision
Name
powerSupplyRevision
Object ID 1.3.6.1.4.1.674.10893.1.20.130.9.1.11
Description Indicates the revision number of the power supply in the enclosure.
Syntax DisplayString
Access Read-only
Power Supply Connection Table
This table describes the connection between each power supply on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Power Supply Connection Table.
Table 1747. Power Supply Connection Table
Name
powerSupplyConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10
Description Defines the power supply connection table.
Syntax SEQUENCE OF PowerSupplyConnectionEntry
Access Not accessible
Table 1748. Power Supply Connection Entry
Name
powerSupplyConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1
Description Defines the power supply connection table entry.
Syntax PowerSupplyConnectionEntry
Access Not accessible
Index
powerSupplyConnectionNumber
Table 1749. Power Supply Connection Number
Name
powerSupplyConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.1
Description Identifies the instance number of the power supply connection entry.
Syntax Integer
Access Read-only
Table 1750. Power Supply Connection Power Supply Name
Name
powerSupplyConnectionPowerSupplyName
Storage Management Group 387