Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1698. Array Disk Enclosure Connection Controller Number
Name
arrayDiskEnclosureConnectionControllerNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.7
Description Identifies the instance number in the controller, table of the controller to which this
array disk is connected.
Syntax Integer
Access Read-only
Array Disk Channel Connection Table
This table describes the connections between array disks, their channel, and their associated controller. For each object in the
table, its object number corresponds to an instance number in the appropriate MIB table for that object where all the object
properties can be found.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by
Storage Management.
The following object sets up the Array Disk Channel Connection Table.
Table 1699. Array Disk Channel Connection Table
Name
arrayDiskChannelConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6
Description Defines the array disk channel connection table.
Syntax SEQUENCE OF ArrayDiskChannelConnectionEntry
Access Not accessible
Table 1700. Array Disk Channel Connection Entry
Name
arrayDiskChannelConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1
Description Defines the array disk channel connection table entry.
Syntax ArrayDiskChannelConnectionEntry
Access Not accessible
Index
arrayDiskEnclosureConnectionNumber
Table 1701. Array Disk Channel Connection Number
Name
arrayDiskChannelConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.1
Description Identifies the instance number of the array disk channel connection entry.
Syntax Integer
Access Read-only
Table 1702. Array Disk Channel Connection Array Disk Name
Name
arrayDiskChannelConnectionArrayDiskName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.6.1.2
Storage Management Group 377