Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1688. Array Disk Cache Policy
Name
arraydiskCachePolicy
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.55
Description Displays the current disk write cache policy of the array disk.
Possible Values:
Enabled - Disabled - Default
Syntax DisplayString
Access Read-only
Table 1689. Array Disk ISE Capable
Name
arraydiskISECapable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.56
Description A boolean value decepting if the disk is Instant Secure Erase Capable or not.
Syntax INTEGER
Access Read-only
Array Disk Enclosure Connection Table
This table describes the connections among array disks, their enclosure, and their associated controller. For each object in the
table, its object number corresponds to an instance number in the appropriate MIB table for that object where all the object
properties can be found.
NOTE:
Only array disks that are part of an enclosure are listed in this table. Backplanes are considered enclosures by
Storage Management.
The following object sets up the Array Disk Enclosure Connection Table.
Table 1690. Array Disk Enclosure Connection Table
Name
arrayDiskEnclosureConnectionTable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5
Description Defines the array disk enclosure connection table.
Syntax SEQUENCE OF ArrayDiskEnclosureConnectionEntry
Access Not accessible
Table 1691. Array Disk Enclosure Connection Entry
Name
arrayDiskEnclosureConnectionEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1
Description Defines the array disk enclosure connection table entry.
Syntax Syntax ArrayDiskEnclosureConnectionEntry
Access Not accessible
Index
Index arrayDiskEnclosureConnectionNumber
Table 1692. Array Disk Enclosure Connection Number
Name
arrayDiskEnclosureConnectionNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.5.1.1
Description Identifies the instance number of the array disk enclosure connection entry.
Storage Management Group 375