Reference Guide

Table Of Contents
Table 1636. Array Disk Vendor (continued)
Syntax DisplayString
Access Read-only
Table 1637. Array Disk State
Name
arrayDiskState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.4
Description Identifies the current state of the array disk.
Possible states:
0: Unknown
1: Ready - Available for use, but no RAID configuration has been assigned.
2: Failed - Not operational.
3: Online - Operational. RAID configuration has been assigned.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.
7: Recovering - Refers to state of recovering from bad blocks on disks.
11: Removed - Indicates that array disk has been removed.
13: Non-RAID - Indicates that array disk is not a RAID capable disk.
14: Not Ready - Applicable for PCIeSSD devices indicating that the device is in locked
state.
15: Resynching - Indicates one of the following types of disk operations: Transform
Type, Reconfiguration, and Check Consistency.
22: Replacing - Indicates copyback operation is in progress.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
34: Predictive Failure
35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC
controllers.
39: Foreign
40: Clear
41: Unsupported
53: Incompatible
56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached
read-only state.
Syntax
Integer
Access Read-only
Table 1638. Array Disk Severity
Name
arrayDiskSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.5
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and
ComponentStatus for each device.
364 Storage Management Group