Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1584. Channel Entry
Name
channelEntry
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1
Description Defines the channel table entry.
Syntax ChannelEntry
Access Not accessible
Index
channelNumber
Table 1585. Channel Number
Name
channelNumber
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.1
Description Identifies the instance number of the channel entry.
Syntax Integer
Access Read-only
Table 1586. Channel Name
Name
channelName
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.2
Description Identifies the name of the channel as represented in Storage Management. The name
includes the word channel and the instance. For example: Channel 1.
Syntax DisplayString
Access Read-only
Table 1587. Channel State
Name
channelState
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.3
Description Identifies the current state of this channel.
Possible states:
0: Unknown
1: Ready - The I/O has resumed.
2: Failed
3: Online
4: Offline - The I/O has paused.
6: Degraded
Syntax Integer
Access Read-only
Table 1588. Channel Severity
Name
channelSeverity
Object ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4
Description This entry is obsolete for Storage Management. It was replaced with RollUpStatus and
ComponentStatus for each device.
Syntax Integer
Storage Management Group 353