Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1563. Controller Storport Driver Version
Name
controllerStorportDriverVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55
Description Provides current Windows OS storport driver version. Not applicable for Linux.
Syntax Octet String
Access Read-only
Table 1564. Controller Minimum Required Storport Version
Name
controllerMinimumRequiredStorportVersion
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.56
Description Provides minimum required storport driver version for Windows OS only.
Syntax Octet String
Access Read-only
Table 1565. Controller Encryption Capable
Name
controllerEncryptionCapable
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.57
Description Indicates encryption capability of the controller. Value: 1 - Capable, 99 - Not Applicable
Syntax Integer
Access Read-only
Table 1566. Controller Encryption Key Persent
Name
controllerEncryptionKeyPresent
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.58
Description Indicates presence of encryption key for the controller.
Value: 1 - Yes, 0 - No, 99 - Not Applicable
Syntax Integer
Access Read-only
Table 1567. Controller Persistent Hot Spare
Name
controllerPersistentHotSpare
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.59
Description Indicates Persistent Hot Spare capability of the controller.
Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined /Not applicable
Syntax Integer
Access Read-only
Table 1568. Controller Spin Down Unconfigured Drives
Name
controllerSpinDownUnconfiguredDrives
Object ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.60
Description Indicates controller capability to put unconfigured drives in power save mode. Value: 1 -
Enabled, 0 - Disabled, 99 - Undetermined /Not applicable