Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 97. Voltage Probe Discrete Reading
Name
voltageProbeDiscreteReading
Object ID 1.3.6.1.4.1.674.10892.5.4.600.20.1.16
Description This attribute defines the reading for a voltage probe of type
voltageProbeTypeIsDiscrete. When the value for voltageProbeType is other than
voltageProbeTypeIsDiscrete, a value is not returned for this attribute. When the
value for voltageProbeType is voltageProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax VoltageDiscreteReadingEnum
Access Read-only
System Information Group
The System Information Group objects provide information about the system in which the iDRAC resides.
Table 98. System Fully Qualified Domain Name
Name
systemFQDN
Object ID 1.3.6.1.4.1.674.10892.5.1.3.1.0
Description This attribute defines the fully qualified domain name of the system.
Syntax StringType
Access Read-only
Table 99. System Service Tag
Name
systemServiceTag
Object ID 1.3.6.1.4.1.674.10892.5.1.3.2.0
Description This attribute defines the service tag of the system.
Syntax StringType
Access Read-only
Table 100. System Express Service Code
Name
systemExpressServiceCode
Object ID 1.3.6.1.4.1.674.10892.5.1.3.3.0
Description This attribute defines the express service code of the system.
Syntax StringType
Access Read-only
Table 101. System Asset Tag
Name
systemAssetTag
Object ID 1.3.6.1.4.1.674.10892.5.1.3.4.0
Description. This attribute defines the asset tag of the system.
Syntax StringType
Access Read-only
Introduction 33