Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 75. Power Usage Idle Power
Name
powerUsageIdlePower
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.15
Description This attribute defines the system idle power (in Watts). This is the minimum power the
system can consume based on the current hardware configuration.
Syntax Unsigned32BitRange
Access Read-only
Table 76. Power Usage Max Potential Power
Name
powerUsageMaxPotentialPower
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.16
Description This attribute defines the system maximum potential power (in Watts). This is the
maximum power the system can consume based on the current hardware configuration.
Syntax Unsigned32BitRange
Access Read-only
Table 77. Power Usage Power Cap Capabilities
Name
powerUsagePowerCapCapabilities
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.17
Description This attribute defines the system power cap capabilities.
Syntax PowerCapCapabilitiesFlags
Access Read-only
Table 78. Power Usage Power Cap Setting
Name
powerUsagePowerCapSetting
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.18
Description This attribute defines the system power cap setting.
Syntax PowerCapSettingEnum
Access Read-only
Table 79. Power Usage Power Cap Value
Name
powerUsagePowerCapValue
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.19
Description This attribute defines the system power cap value (in Watts).
Syntax Unsigned32BitRange
Access Read-only
Table 80. Power Usage Instantaneous Headroom
Name
powerUsageInstantaneousHeadroom
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.20
Description This attribute defines the system instantaneous headroom (in Watts). This is the
theoretical maximum power drawn by the power supply minus instantaneous power
draw.
Syntax Unsigned32BitRange