Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 58. Power Supply Rated Input Wattage (continued)
Access Read-only
Table 59. Power Supply FQDD
Name
powerSupplyFQDD
Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.15
Description Fully qualified device descriptor (FQDD) of the power supply.
Syntax FQDDString
Access Read-only
Table 60. Power Supply Current Input Voltage
Name
powerSupplyCurrentInputVoltage
Object ID 1.3.6.1.4.1.674.10892.5.4.600.12 .1.16
Description This attribute defines the current input voltage to the power supply (in Volts).
Syntax PowerSupplyConfigurationErrorTypeEnum
Access Read-only
Power Usage Table
The Power usage objects provide information about the power usage in which the iDRAC resides.
Table 61. Power Usage Chassis Index
Name
powerUsageChassisIndex
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.1
Description This attribute defines the index (one based) of the associated system chassis.
Syntax ObjectRange
Access Read-only
Table 62. Power Usage Index
Name
powerUsageIndex
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.2
Description This attribute defines the index (one based) of the power usage information.
Syntax ObjectRange
Access Read-only
Table 63. Power Usage State Capabilities
Name
powerUsageStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.5.4.600.60.1.3
Description This attribute defines the state capabilities of the power usage information.
Syntax StateCapabilitiesFlags
Access Read-only
26 Introduction