Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 1024. Managed System Services Device Type
Variable Name:DellManagedSystemServicesDeviceType
Data Type:Integer
Possible Data Values Meaning of Data Value
baseDevice(0)
Device type is base device.
optionalDevice(1)
Device type is optional device.
Table 1025. SD Card Device Type
Variable Name:DellSDCardDeviceType
Data Type:Integer
Possible Data Values Meaning of Data Value
other(1)
Device type is other.
unknown(2)
Device type is unknown.
hypervisor(3)
Device type is Hypervisor.
vFlash(4)
Device type is Virtual Flash (vFlash.)
Table 1026. SD Card Device Config Capabilities
Variable Name:DellSDCardDeviceConfigCapabilities
Data Type:Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0)
SD card device has none of the following capabilities.
sdCapable(1)
SD media can be enabled.
vFlashCapable(2)
Virtual Flash (vFlash) can be enabled.
Table 1027. SD Card Device Config Settings
Variable Name:DellSDCardDeviceConfigSettings
Data Type:Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values Meaning of Data Value
none(0)
SD card device has none of the following settings.
sdEnabled(1)
SD media is enabled.
vFlashEnabled(2)
Virtual Flash (vFlash) is enabled.
Table 1028. SD Card Device Card State
Variable Name:DellSDCardDeviceCardState
Data Type:Integer
Possible Data Values Meaning of Data Value
none(0)
SD card state is none of the following states.
present(1)
Device is present.
ipmiReady(2)
Device is IPMI ready.
Server Administrator Group 235