Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 42. Power Supply Count For Redundancy
Name
powerSupplyCountForRedundancy
Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.6
Description This attribute defines the total number of power supplies required for this power unit to
have full redundancy.
Syntax ObjectRange
Access Read-only
Table 43. Power Unit Name
Name
powerUnitName
Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.7
Description This attribute defines the name of the power unit.
Syntax String64
Access Read-only
Table 44. Power Unit Status
Name
powerUnitStatus
Object ID 1.3.6.1.4.1.674.10892.5.4.600.10.1.1.8
Description This attribute defines the status of the power unit.
Syntax ObjectStatusEnum
Access Read-only
Power Supply Table
The Power Supply objects provide information about the system power supply in which the iDRAC resides.
Table 45. Power Supply Chassis Index
Name
powerSupplychassisIndex
Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.1
Description This attribute defines the index (one based) of the system chassis.
Syntax PowerSupplyTableEntry
Access Read-only
Table 46. Power Supply Index
Name
powerSupplyIndex
Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.2
Description This attribute defines the index (one based) of the power supply.
Syntax ObjectRange
Access Read-only
Table 47. Power Supply State Capabilities Unique
Name
powerSupplyStateCapabilitiesUnique
Object ID 1.3.6.1.4.1.674.10892.5.4.600.12.1.3
Introduction 23