Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 997. Pointing Device Type (continued)
deviceTypeIsATrackPoi
nt(5)
Device type is a track point.
deviceTypeIsAGlidePoi
nt(6)
Device type is a glide point.
deviceTypeIsATouchPad
(7)
Device type is a touch pad.
Table 998. Processor Device Status State
Variable Name:DellProcessorDeviceStatusState
Data Type:Integer
Possible Data Values Meaning of Data Value
other(1)
Processor device type is not one of the following:
unknown(2)
Device type is unknown.
enabled(3)
Device is enabled.
userDisabled(4)
Device is disabled by the user.
biosDisabled(5)
Device has its BIOS disabled.
idle(6)
Device is idle.
Table 999. Processor Device Status Reading
Variable Name:DellProcessorDeviceStatusReading
Data Type:Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
internalError(1)
The processor experienced an internal error
thermalTrip(2)
The processor experienced a thermal trip
configurationError(
32)
The processor experienced a configuration error
processorPresent(12
8)
The processor is present
processorDisabled(2
56)
The processor is disabled
terminatorPresent(5
12)
The terminator is Present
processorThrottled(
1024)
The processor is throttled
Table 1000. Processor Device Type
Variable Name:DellProcessorDeviceType
Data Type:Integer
Possible Data Values Meaning of Data Value
deviceTypeIsOther(1
)
The processor device type is not one of the following
values:
216 Server Administrator Group