Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 955. Network Device Teaming Flags
Name
networkDeviceTeamingFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.22
Description Defines the teaming features of the network device.
Syntax DellNetworkDeviceTeamingFlags (See Network Device Teaming Flags)
Access Read-only
Table 956. Network Device TOE Capability Flags
Name
networkDeviceTOECapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23
Description Defines the TCP/IP Offload Engine (TOE) capability flags of the network device.
Syntax DellNetworkDeviceTOECapabilityFlags (See Network Device TOE Capability Flags)
Access Read-only
Table 957. Network Device TOE Enabled
Name
networkDeviceTOEEnabled
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.24
Description Defines if TOE is enabled for the network device.
Syntax DellBoolean
Access Read-only
Table 958. Network Device RDMA Capability Flags
Name
networkDeviceRDMACapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.25
Description Defines the Remote Direct Memory Access (RDMA) capability flags of the network
device.
Syntax DellNetworkDeviceRDMACapabilityFlags (See Network Device RDMA Capability Flags)
Access Read-only
Table 959. Network Device RDMA Enabled
Name
networkDeviceRDMAEnabled
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.26
Description Defines if RDMA is enabled for the network device.
Syntax DellBoolean
Access Read-only
Table 960. Network Device iSCSI Capability Flags
Name
networkDeviceiSCSICapabilityFlags
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.27
Description Defines the Internet Small Computer System Interface (iSCSI) capability flags of the
network device.
Syntax DellNetworkDeviceiSCSICapabilityFlags (See Network Device iSCSI Capability Flags)
Access Read-only
208 Server Administrator Group