Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 949. Network Device Permanent MAC Address
Name
networkDevicePermanentMACAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.16
Description Defines the permanent MAC address of the network device.
Syntax DellMACAddress
Access Read-only
Table 950. Network Device PCI Bus Number
Name
networkDevicePCIBusNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.17
Description Defines the PCI bus number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only
Table 951. Network Device PCI Device Number
Name
networkDevicePCIDeviceNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.18
Description Defines the PCI device number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only
Table 952. Network Device PCI Function Number
Name
networkDevicePCIFunctionNumber
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.19
Description Defines the PCI function number of the network device.
Syntax DellUnsigned8BitRange
Access Read-only
Table 953. Network Device IRQ
Name
networkDeviceIRQ
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.20
Description Defines the interrupt request number of the network device.
Syntax DellUnsigned32BitRange
Access Read-only
Table 954. Network Device Base IO Port Address
Name
networkDeviceBaseIOPortAddress
Object ID 1.3.6.1.4.1.674.10892.1.1100.90.1.21
Description Defines the base input/output port address of the network device.
Syntax DellUnsigned32BitRange
Access Read-only
Server Administrator Group 207