Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 887. Memory Device Mapped Address Index (continued)
Access Read-only
Table 888. Memory Device Mapped Address State Capabilities
Name
memoryDeviceMappedAddressStateCapabilities
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.3
Description Defines the capabilities of the memory device mapped address.
Syntax DellStateCapabilities
Access Read-only
Table 889. Memory Device Mapped Address State Settings
Name
memoryDeviceMappedAddressStateSettings
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.4
Description Defines the state of the memory device mapped address.
Syntax DellStateSettings
Access Read-only
Table 890. Memory Device Mapped Address Status
Name
memoryDeviceMappedAddressStatus
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.5
Description Defines the status of the memory device mapped address.
Syntax DellStatus
Access Read-only
Table 891. Memory Device Index Reference
Name
memoryDeviceIndexReference
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.6
Description Defines the index of the memory device(s) associated with this memory device mapped
address.
Syntax DellObjectRange
Access Read-only
Table 892. Memory Device Mapped Address Row Position
Name
memoryDeviceMappedAddressRowPosition
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.7
Description Defines the position of the referenced memory in a row of the memory device mapped
address.
Syntax DellUnsigned32BitRange
Access Read-only
Table 893. Memory Device Mapped Address Interleave Position
Name
memoryDeviceMappedAddressInterleavePosition
Object ID 1.3.6.1.4.1.674.10892.1.1100.60.1.8
196 Server Administrator Group