Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 841. Cache Device Maximum Size
Name
cacheDeviceMaximumSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.12
Description Defines the maximum size of the cache device in kilobytes (KB). A zero (0) indicates
that the size is unknown.
Syntax DellUnsigned32BitRange
Access Read-only
Table 842. Cache Device Current Size
Name
cacheDeviceCurrentSize
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13
Description Defines the current size of the cache device in KB. A zero (0) indicates that the size is
unknown.
Syntax DellUnsigned32BitRange
Access Read-only
Table 843. Cache Device Speed
Name
cacheDeviceSpeed
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.14
Description Defines the speed of the cache device in nanoseconds. A zero (0) indicates that the
speed is unknown.
Syntax DellUnsigned32BitRange
Access Read-only
Table 844. Cache Device Write Policy
Name
cacheDeviceWritePolicy
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.15
Description Defines the write policy of the cache device.
Syntax DellCacheDeviceWritePolicy (See Cache Device Write Policy)
Access Read-only
Table 845. Cache Device Is Socketed
Name
cacheDeviceIsSocketed
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.16
Description Defines if the cache device is socketed.
Syntax DellBoolean
Access Read-only
Table 846. Cache Device Error Checking and Correction (ECC) Type
Name
cacheDeviceECCType
Object ID 1.3.6.1.4.1.674.10892.1.1100.40.1.17
Description Defines the type of error correction in use by the cache device.
Syntax DellCacheDeviceECCType (See Cache Device ECC Type)
Server Administrator Group 187