Reference Guide

Table Of Contents
Table 642. Temperature Probe Type
Variable Name: DellTemperatureProbeType
Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureProbeTypeIsOther(1)
The temperature probe subtype is not one of the following:
temperatureProbeTypeIsUnknown(2)
The temperature probe subtype is unknown (not known or not
monitored).
temperatureProbeTypeIsAmbientESM(3)
The temperature probe is for ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16)
The temperature probe subtype is a temperature probe with
discrete reading.
Table 643. Temperature Probe Discrete Reading
Variable Name: DellTemperatureDiscreteReading
Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureIsGood(1)
The temperature probe discrete reading is good.
temperatureIsBad(2)
The temperature probe discrete reading is bad.
Remote Flash BIOS Group
The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system.
The variables also define the capabilities of BIOS updates on the system.
Remote Flash BIOS Group Table
The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.
Remote Flash BIOS Table
The following object sets up the Remote Flash BIOS Table:
Table 644. Remote Flash BIOS Table
Name
remoteFlashBIOSTable
Object ID 1.3.6.1.4.1.674.10892.1.900.10
Description Defines the Remote Flash BIOS Table.
Syntax RemoteFlashBIOSTableEntry
Access Not accessible
Table 645. Remote Flash BIOS Table Entry
Name
remoteFlashBIOSTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1
Description Defines the Remote Flash BIOS Table entry.
Syntax RemoteFlashBIOSTableEntry
Server Administrator Group 147