Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 642. Temperature Probe Type
Variable Name: DellTemperatureProbeType
Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureProbeTypeIsOther(1)
The temperature probe subtype is not one of the following:
temperatureProbeTypeIsUnknown(2)
The temperature probe subtype is unknown (not known or not
monitored).
temperatureProbeTypeIsAmbientESM(3)
The temperature probe is for ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16)
The temperature probe subtype is a temperature probe with
discrete reading.
Table 643. Temperature Probe Discrete Reading
Variable Name: DellTemperatureDiscreteReading
Data Type: Integer
Possible Data Values Meaning of Data Value
temperatureIsGood(1)
The temperature probe discrete reading is good.
temperatureIsBad(2)
The temperature probe discrete reading is bad.
Remote Flash BIOS Group
The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to remotely update the BIOS in a system.
The variables also define the capabilities of BIOS updates on the system.
Remote Flash BIOS Group Table
The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.
Remote Flash BIOS Table
The following object sets up the Remote Flash BIOS Table:
Table 644. Remote Flash BIOS Table
Name
remoteFlashBIOSTable
Object ID 1.3.6.1.4.1.674.10892.1.900.10
Description Defines the Remote Flash BIOS Table.
Syntax RemoteFlashBIOSTableEntry
Access Not accessible
Table 645. Remote Flash BIOS Table Entry
Name
remoteFlashBIOSTableEntry
Object ID 1.3.6.1.4.1.674.10892.1.900.10.1
Description Defines the Remote Flash BIOS Table entry.
Syntax RemoteFlashBIOSTableEntry
Server Administrator Group 147