Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 588. CPU Power Performance Management Type (continued)
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
CPU power and performance management type is Maximum
Performance.
minPower(2)
CPU power and performance management type is Minimum
Power.
osDBPM(4)
CPU power and performance management type is OS Demand
Based Power Management.
systemDBPM(8)
CPU power and performance management type is System
Demand Based Power Management.
Table 589. Memory Power Performance Management Type
Variable Name: DellMemoryPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Memory power and performance management type is
Maximum Performance.
mhz1333(2)
Memory power and performance is 1333 MHz. .
mhz1067(4)
Memory power and performance is 1067 MHz.
mhz800(8)
Memory power and performance is 800 MHz.
minPower(16)
Memory power and performance management type is
Minimum Power.
Table 590. Fan Power Performance Management Type
Variable Name: DellFanPowerPerformanceManagementType
Data Type: Integer
NOTE:
These values are bit masks, so combination values are possible.
Possible Data Values Meaning of Data Value
maxPerformance(1)
Fan power and performance management type is Maximum
Performance.
minPower(2)
Fan power and performance management type is Minimum
Power.
Thermal Group
The Thermal Group provides information about cooling units, cooling devices, and temperature probes. Cooling units are sets of
fans or other cooling devices in a system chassis. Thermal Group variables include threshold values and types of cooling devices
and temperature probes.
136
Server Administrator Group