Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 568. Power Profile Custom Fan Management Capabilities (continued)
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.9
Description Defines the custom fan power and performance management capabilities that are
available for the Custom power profile.
Syntax DellFanPowerPerformanceManagementType
Access Read-only
Table 569. Power Profile Custom Fan Management Setting
Name
powerProfileCustomFanManagementSetting
Object ID 1.3.6.1.4.1.674.10892.1.600.70.1.10
Description Defines the custom fan power and performance management setting for the Custom
power profile.
Syntax DellFanPowerPerformanceManagementType
Access Read-only
Power Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 570. Power Supply State Capabilities Unique
Variable Name: DellPowerSupplyStateCapabilitiesUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onlineCapable(2)
The power supply can be disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4)
The power supply’s capabilities are not ready.
Table 571. Power Supply State Settings Unique
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onLine(2)
The power supply’s state is disabled (offline, a binary 0 value)
or enabled (online, a binary 1 value).
notReady(4)
The power supply’s state is not ready.
fanFailure(8)
The power supply fan has failed.
onlineAndFanFailure(10)
The power supply is online and indicating that its fan is not
working.
powerSupplyIsON(16)
The power supply is indicating that it is on.
powerSupplyIsOk(32)
The power supply is indicating that it is OK.
acSwitchIsON(64)
The power supply is indicating that the AC power switch is on.
onlineandAcSwitchIsON (66)
The power supply is online and indicating that the AC power
supply switch capability is activated.
130 Server Administrator Group