Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 463. Power Supply Power Unit Index Reference (continued)
Access Read-only
Table 464. Power Supply Sensor State
Name
powerSupplySensorState
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.11
Description Defines the state reported by the power supply sensor, and supplements the state and
settings of the power supply.
Syntax DellPowerSupplySensorState (Power Supply Sensor State)
Access Read-only
Table 465. Power Supply Configuration Error Type
Name
powerSupplyConfigurationErrorType
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.12
Description Defines the type of configuration error reported by the power supply sensor.
Syntax DellPowerSupplyConfigurationErrorType (Power Supply Configuration Error Type)
Access Read-only
Table 466. Power Supply Power Monitor Capable
Name
powerSupplyPowerMonitorCapable
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.13
Description Defines a boolean value that reports whether the power supply is capable of monitoring
power consumption.
Syntax DellBoolean
Access Read-only
Table 467. Power Supply Rated Input Wattage
Name
powerSupplyRatedInputWattage
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.14
Description Defines the rated input wattage of the power supply (in tenths of Watts.)
Syntax DellSigned32BitRange
Access Read-only
Table 468. Power Supply FQDD
Name
powerSupplyFQDD
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.15
Description Fully qualified device descriptor (FQDD) of the power supply.
Syntax FQDDString
Access Read-only
Table 469. Power Supply Current Input Voltage
Name
powerSupplyCurrentInputVoltage
Object ID 1.3.6.1.4.1.674.10892.1.600.12.1.16
Description This attribute defines the current input voltage to the power supply (in Volts).
Server Administrator Group 111