Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 4. Server Administrator Storage Management MIB Sections in This Guide (continued)
Section Topics MIB Group Numbers
● Storage Management Information Group
● Global Data Group
● Physical Devices Group
● Logical Devices Group
● Storage Management Event Group
● Software Group
20
NA
NA
130
140
NA
1
27 Storage Management Alert Reference — lets you monitor the health
of storage resources such as controllers, connectors, array disks, and
virtual disks
NA
Server Administrator Field Replaceable Unit MIB
The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information about field replaceable unit
(FRU) hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar objects or MIB tables that
provide related information. The following table describes each Server Administrator Field Replaceable Unit MIB group and lists
the MIB group number assigned to the MIB group. The Server Administrator Field Replaceable Unit MIB groups are identified by
the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number assigned to
the MIB group. See the relevant section for more information about the MIB objects defined in a MIB group.
Table 5. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section Topic MIB Group Numbers
22 Field Replaceable Unit Group — provides information about field
replaceable units that may be present in your system
2000
Server Administrator Change Management MIB
The Server Administrator Change Management MIB (filename dellcm.mib) provides management data that allows you to
monitor the inventory of devices and applications with SNMP management applications.
The following table describes each Server Administrator Change Management MIB group and lists the MIB group number
assigned to the MIB group. The Server Administrator Change Management MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the
relevant section for more information about the MIB objects defined in a MIB group.
Table 6. Server Administrator Change Management MIB Sections in This Guide
Section Topics MIB Group Number
24 Change Management Group - describes the
inventory data provided by the Change
Management MIB that allows users to monitor
devices and software present on a particular
managed computer chassis
10899
Introduction 11