Reference Guide
Table Of Contents
- Dell EMC OpenManage SNMP Reference Guide Version 10.1.0.0
- Contents
- Introduction
- What is new in this release
- Supported SNMP Versions
- Managed Object Used in This Document
- Server Administrator Instrumentation MIB
- Server Administrator Baseboard Management Controller, ASF MIB
- Server Administrator Storage Management MIB
- Server Administrator Field Replaceable Unit MIB
- Server Administrator Change Management MIB
- Basic Terminology
- Frequently Used Terms in Variable Names
- Tables
- Section Organization
- Other Documents You May Need
- Introduction to the Server Administrator SNMP Subagent
- System Battery Table
- Amperage Probe Table
- Power Unit Group
- Power Supply Table
- Power Usage Table
- Voltage Probe Table
- System Information Group
- Server Administrator Group
- Instrumentation MIB Version Group
- Systems Management Software Group
- System State Group
- Chassis Information Group
- Operating System Group
- System Resource Group
- Power Group
- Thermal Group
- Remote Flash BIOS Group
- Port Group
- Device Group
- Device Tables
- Pointing Device Table
- Keyboard Device Table
- Processor Device Table
- Processor Device Status Table
- Cache Device Table
- Memory Device Table
- Memory Device Mapped Address Table
- Generic Device Table
- PCI Device Table
- PCI Device Configuration Space Table
- Network Device Table
- Managed System Services Device Table
- SD Card Unit Table
- SD Card Device Table
- Device Group Variable Values
- Device Tables
- Slot Group
- Memory Group
- BIOS Setup Control Group
- Local Response Agent Group
- Cost of Ownership Group
- Cluster Group
- Baseboard Management Controller Group
- Field Replaceable Unit Group
- Storage Management Group
- Storage Management Group
- Storage Management Information Group
- Global Data Group
- Physical Devices Group
- Controller Table
- Channel Table
- Enclosure Table
- Array Disk Table
- Array Disk Enclosure Connection Table
- Array Disk Channel Connection Table
- Fan Table
- Fan Connection Table
- Power Supply Table
- Power Supply Connection Table
- Temperature Probe Table
- Temperature Probe Connection Table
- Enclosure Management Module Table
- Enclosure Management Module Connection Table
- Battery Table
- Battery Connection Table
- Tape Drive Table
- NVME adapter table
- Logical Devices Group
- Storage Management Event Group
- Change Management Group
- SNMP Traps
- Storage Management Alert Reference
- Standard Data Type Definitions
- SNMP Sample Output
Table 438. Resource Interrupt Type (continued)
interruptIsLevelSensitive(
1)
The interrupt type is level sensitive.
interruptIsLatched(2)
The interrupt type is latched.
Table 439. Resource Interrupt Trigger
Variable Name: DellResourceInterruptTrigger
Data Type: Integer
Possible Data Values Meaning of Data Value
interruptIsActiveWhenLow(1
)
The interrupt trigger is active on a low signal.
interruptIsActiveWhenHigh(
2)
The interrupt trigger is active on a high signal.
Table 440. Resource DMA Bus Primary
Variable Name: DellResourceDMABusPrimary
Data Type: Integer
Possible Data Values Meaning of Data Value
dmaIsOther(1)
The DMA bus control capability is not one of the following:
dmaIsUnknown(2)
The DMA bus control capability is unknown.
dmaIsNotABusmaster(3)
The DMA does not have any bus control capability.
Table 441. Resource DMA Transfer Width
Variable Name: DellResourceDMATransferWidth
Data Type: Integer
Possible Data Values Meaning of Data Value
dmaTransferWidthIsOther(1)
The DMA transfer width is not one of the following:
dmaTransferWidthIsunknown(
2)
The DMA transfer width is unknown.
dmaTransferWidthIs8Bits(3)
The DMA transfer width is 8 bits.
dmaTransferWidthIs16Bits(4
)
The DMA transfer width is 16 bits.
dmaTransferWidthIs32Bits(5
)
The DMA transfer width is 32 bits.
dmaTransferWidthIs64Bits(6
)
The DMA transfer width is 64 bits.
dmaTransferWidthIs128Bits(
7)
The DMA transfer width is 128 bits.
Power Group
The Power Group provides information about power units (a group of power supplies in a system chassis), power supplies, and
voltage and amperage probes.
NOTE:
Power Management features are only available for PowerEdge systems that have hot-swappable power supplies
and not systems that have a fixed, nonredundant power supply installed.
106 Server Administrator Group