Release Notes
Table Of Contents
- Dell EMC OpenManage Server Administrator Release Notes Version 10.1.0.0
- Product description
- OMSA Customer Survey
- Platforms Affected
- Requirements
- What is new in this release
- Installation Procedure
- Known issues and workarounds for Server Administrator
- User notes
- Storage Management Service
- Installation Prerequisites
- Known issues and workarounds for Storage Management Service
- User notes for Storage Management Service
- List of firmware for PERC controllers
- List of firmware for BOSS controllers
- Microsoft Windows Drivers for PERC and BOSS Controllers
- Linux and VMware ESXi Drivers for PERC and BOSS Controllers
- Copyright
Table 1. Issues of Server Administrator on all supported operating systems (continued)
Issue ID Functional area Description Workaround/Resolution
event filters related to a power monitoring
as System Power Probe Warning and
System Power Probe Failure. These two
filters are not supported on these systems.
That is, you can view and configure these
filters, but no action is taken.
Not
available
Simultaneously logging into
multiple browsers using
SSO
Due to some limitations, you cannot log
on simultaneously to multiple browser
instances/tabs using SSO login, as only
one session remains active while the other
sessions expire.
Not available
DF549057 BIOS attributes as read-
only
When an operating system is installed
through USC, the BIOS attributes in Server
Administrator are displayed as read-only.
You can edit the BIOS attributes 18 hours
after the operating system installation.
To enable editing of the Server
Administrator BIOS attributes,
launch Lifecycle Controller while
booting.
BITS040169 Boot/HDD/UEFI sequence In case of Boot/HDD/UEFI sequence, if they
are read-only, then toggle buttons (+ and
-) and submit button are not visible. On
the BIOS setup page, dependencies may
exist between the various attributes for
Bios settings. Setting an attribute value
may change the state of the dependent
attributes to non-editable or editable. For
example, changing the Boot Mode to UEFI
from the Boot Settings page does not allow
you to configure the Boot or Hard-Disk
Drive Sequence in the BIOS Boot Settings
page. When the page is non-editable, the
toggle buttons on the page allows toggling
the order of the boot sequence. However,
settings cannot be configured since Apply
button will not available to submit the
settings.
Not available
Not
available
Restore the previous
certificate
If a new certificate imported to Server
Administrator is not active after restarting
the web server, restore the previous
certificate.
To restore the previous certificate,
do the following:
1. Stop the web server.
2. Perform one of the following as
applicable:
● On systems running
Windows:
○ Delete the file
keystore.db at
<installed
directory>\Dell\Sy
sMgt\apache-
tomcat\conf\
○ Rename the file
keystore.db.bak at
<installed
directory>\Dell\Sy
sMgt\apache-
tomcat\conf\ to
keystore.db
● On systems running Linux:
8