Table 1. Issues of Server Administrator on all supported operating systems (continued)
Issue ID Functional area Description Workaround/Resolution
files\dell\SysMgt\apach
e-tomcat\conf.
3. Copy keystore.db.bak to
keystore.db
4. Type omconfig system
webserver action=start
Not
available
Temperature drop below
threshold
A temperature drop below a minimum failure
threshold does not cause a system reset
even if this alert action is set.
Not available
Not
available
Boot sequence Selecting the boot sequence under the BIOS
Setup tab does not re-enable boot devices
that have been disabled in the System Setup
Program earlier.
Not available
Not
available
Unsecured HTTP requests All unsecured HTTP requests to Server
Administrator receive an invalid response.
Server Administrator runs only one instance
of the Web server, which is secure. Make all
connections through https://<ip address>:
<port number>. Any http://<ip address>:
<port number> request for connection with
the server receives an invalid response.
Not available
Not
available
Temperature in whole
numbers
On some systems, temperature probe values
and settings are only supported for whole
degrees, not tenths of a degree. On those
systems, setting a fractional value for the
minimum warning temperature threshold
results in the set value being rounded off to
the next whole number value. This behavior
may cause the minimum warning threshold
to have the same value as the minimum
failure threshold.
Not available
Not
available
Session Management If you close the browser using the Close
button on the browser or log off from the
operating system, the Server Administrator
session is not terminated. This session is
listed in the Session Management page
until the session time out occurs, or DSM
SA connection service is restarted, or the
operating system reboot.
Not available
Not
available
Operating system time zone If you change the operating system
Time Zone to a new time zone, Server
Administrator session management does not
display the time in the new time zone
specified.
Restart Server Administrator to
display the accurate time for
the time zone in the Session
Management page.
DF152755 OMSA GUI response The Server Administrator UI does not
respond when the alerts log has many
events. If the Alert Log contains several
entries and if you try to navigate to another
page, the Server Administrator GUI may take
about 30 seconds to display the content.
Not available
DF172125 Power monitoring probes Power monitoring probes are displayed
on certain systems that do not support
power monitoring. On certain systems that
do not support power monitoring, Server
Administrator reports the two platform
Not available
7