Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
Hence, if there are any earlier events present in
memory, then the OMSA will regenerate those events.
Performing LC wipe cannot clear the earlier events
completely.
188961,
200121
Core dump
generated while
stopping the dcim
service
If HBA 10, HBA 11, or PERC 310 controller is present
in the server, then OpenManage generates a core
dump while stopping the dcim service. The dcim service
stops at several other instances such as upgrading
OpenManage, uninstalling OpenManage, and so on.
Not available
Not available Not available When there is a failed drive on HBA controller, any
storage-related task execution or the alert processing
will take more time.
Not available
191175 BOSS Console
driver
If the BOSS Console driver is upgraded when OMSA is
started, then you must restart the server to make the
updated driver become effective
Not available
196564 Service Control
Manager displays a
1053 error
On Windows operating system, if the DataManager
service is either stopped or restarted before completing
the enumeration of the storage tree, the Service
Control Manager displays a 1053 error. Thus, as the
result DataManager service stops responding, and the
status is displayed as Stopping.
Restart the server
199921 Physical drive
removal event is
not logged
If a connection to an enclosure is terminated and a
Communication Lost event (ENC18) for that enclosure
is received, then the Physical Drive Removed event for
all connected physical drives might not be logged.
Not available
188971 OMSS UI is
unresponsive
The OMSS UI might not respond for sometime and
enumeration might be incorrect, when the continuous
I/O errors are reported on physical drives connected
to an enclosure with SAS 12 Gbps HBA controller on
Ubuntu 20.04.X operating system.
Not available
198990 Multipath
enumeration is not
updated
On HBA 355 external controller connected to
Array584EMM or MD14XX enclosures, the multipath
enumeration might not update intermittently, when the
redundant path is disrupted.
Restart the OpenManage
DataManager service.
User notes for Storage Management Service
Detailed information on the Storage Management Service is available in the Storage Management Service online help. After
installing and launching Server Administrator, you can access the Storage Management Service online help by selecting the
Storage or lower-level tree object and clicking the Help button on the global navigation bar.
List of firmware for PERC controllers
Table 7. List of Firmware for PERC controllers
Controller Firmware/BIOS
PERC H800 Adapter 12.10.7-0001
PERC H700 Integrated 12.10.7-0001
PERC H700 Adapter 12.10.7-0001
26