Release Notes

Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
openmanage/ and other
operating systems : /opt/
dell/srvadmin/var/log/
openmanage/.
169111 Partial RAID-10 VDs On a partial RAID-10 virtual disk creation through
Create virtual disk advanced wizard, the drive selection
list displayed may not be similar to the actual physical
drive associated with the spans.
Not available
168698 Enumeration on
ESXi
Read Only Write-Protected drive will not enumerate on
systems running ESXi operating systems.
Not available
155954 Hot-plug-in multiple
drives of MX5016s
While hot-plug-in multiple drives of MX5016s physically,
wait for each insert alert to avoid the wrong
enumeration.
Restart the Data manager
service to get the updated
enumeration.
Not available Controller ID and
name
If the controller name is not displayed in the alert
message, check the controller information for mapping
the controller ID and controller name.
Not available
92467 Dynamic mapping The dynamic mapping of an enclosure for the first time
also displays the unmapped enclosure for a short period.
Refresh the Server Administrator page to remove the
unmapped enclosure entries.
Not available
Not available Polling interval To determine the changes made on an enclosure
connected to HBA 11 controller and later versions, the
polling interval is set to five minutes. Therefore, it takes
approximately six minutes to generate an enclosure
event report and update its properties. However, if a
change it made to the enclosure environment status but
reverted to the previous status within this predefined
five minutes, then an event is not recorded. For
example, if a fan is removed but installed back within
five minutes, then an event is not recorded for this
purpose.
Not available
94402 Alerts are not
displayed
The alerts are not displayed when a physical disk is
inserted or removed on enclosure MX5016s mapping or
unmapping.
186184,
187434
Enclosure alerts If an enclosure is connected to HBA 355e controller,
then some of the enclosure-related alerts such as EMM
events, FAN events, PSU events Redundancy lost,
Redundancy restored events are not generated.
Restart DataManager service
to update a component status.
178110 Non-RAID drives If non-RAID predictive failure drives are connected to
enclosures, then the enclosure status may not always
be indicated as READY.
Not available
175332 Operations are
delayed or stopped
responding
On Storage Management, operations may be delayed or
may not respond for some time, whenever the physical
disks or enclosures are inserted, mapped, removed, or
unmapped from MX5016s.
Not available
179687 Initialization error If NVMe drive with initialization error is connected, then
that slot will not enumerate in slot occupancy report
and total slot count will be less.
Not available
Not available BOSS-related alerts
starts from number
0
When OpenManage Server Administrator (OMSA) is
installed on a newly installed operating system, it starts
reading BOSS-related alerts from sequence number 0.
Not available
25