Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
SATA or NVMe belonging to a span in one virtual disk.
This might be distributed across the spans for another
virtual disk formed on the same disk group.
151463 Slot occupancy
report
On RHEL 7.7 and SLES 15 SP1 the slots occupancy
report does not display the empty slot available for
HBA330 controller.
Not available
153490 Slot occupancy
report
On PowerEdge R7515 system with 8 SAS or SATA and
16 NVMe backplane configuration, the slot occupancy
report for hardware PERC controller displays as 12 slots
instead of 8 slots that are connected to hardware PERC
controller.
Not available
143512 EMM alert
generation
The EMM alert generation is delayed if there are failed
drives present in the enclosure.
Not available
Not available Export log Export log operation may fail for failed state drive. Not available
Not available Failed drive
enumeration
Part Number, Serial No, Product ID, Vendor ID,
Firmware Revision, Sub-vendor ID, Model Number
values may not enumerate for failed state drive.
Not available
162168 (CR) Toshiba NVMe
drive
Sometimes when the Toshiba NVMe drive on the
SWRAID controller is connected (and is part of a Virtual
Disk), or a failed NVMe drive is present in the system.
There can be multiple PDR211 alerts that are logged
in the alert log page. The logs can lead to delayed of
response on the GUI.
Not available
161708 Data transfer on
M.2 drives
If the data transfer is not performing on M.2 drives
while performing hot-plug out operation, then after hot
plug-in back the same, the virtual disk rebuild alert will
not be generated. The virtual disk status will change
from degraded to online.
Not available
Not available PCIe subsystems The Device name field of NVMe drives is displayed as
char device name on PCIe subsystems running on Linux
operating.
Not available
165785 Read-write policy
on S130
On S130 and later, any change in read and write policy
values while creation of virtual disks does not reflect on
virtual disk.
Use Change policy virtual
disk task for changing these
policies.
165788 Predictive failure
drives
Predictive failure drives on HBA controller displays as
ready state and the predictive failure alert is also not
generated for such drives.
Not available
167651 PCIe subsystem The Storage Management enumerates the PCIe
Subsystem controller also for 2.5' NVMe drives on
PERC 11.
Not available
Not available Auto-configure
RAID 0
When the auto-configure RAID 0 task is performed on
PERC 9, only HDDs that are currently in ready state will
change to RAID 0. There will be no change for SSDs.
Not available
165719 Storage Alert Log A blank page of the Storage Alert Log is displayed when
the Storage controller generates several alerts and cold
boot performed together from iDRAC.
Delete dcsys64.xml and
restart the services. The
file path where the .xml
file is available on systems
running Microsoft Window
operating system : C:\Program
Files\Dell\SysMgt\omsa\log,
on systems running ESXi
operating system : /etc/cim/
dell/srvadmin/var/log/
24