Release Notes
Table Of Contents
- Dell EMC OpenManage Server Administrator Release Notes Version 10.1.0.0
- Product description
- OMSA Customer Survey
- Platforms Affected
- Requirements
- What is new in this release
- Installation Procedure
- Known issues and workarounds for Server Administrator
- User notes
- Storage Management Service
- Installation Prerequisites
- Known issues and workarounds for Storage Management Service
- User notes for Storage Management Service
- List of firmware for PERC controllers
- List of firmware for BOSS controllers
- Microsoft Windows Drivers for PERC and BOSS Controllers
- Linux and VMware ESXi Drivers for PERC and BOSS Controllers
- Copyright
Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
Recommendation : It is recommended to wait for the
Redundant path broken alerts before performing the
clear redundant path. If in case Server Administrator
page delay is observed, wait for few minutes to return
to the normal state page or restart the service.
120251 Orphan drive The foreign physical disks connected to the system, on
reaching the maximum number of supported virtual disk
by the controller is displayed on the Import Preview
page as Orphan Drive.
Not available
117872 Unblink operation On performing the unblink operation on physical disk
connected to 12Gbps SAS HBA, observing both health
and activity LEDs light turn off.
Not available
128978 Import foreign
configuration task
is not successful
When there is failed virtual disk in the same controller
the Import foreign configuration on controller’s task,
does not list the available degraded virtual disks to
import, recover or clear. The list can be observed after
failed virtual disk deletion.
Not available
Not available The Submit button On UI if the submit button is clicked more than once an
internal error may occur, but the task will be performed
successfully.
Not available
132214 Managed preserved
task
Few minutes delay occurs to disable the Managed
preserved cache task from the task list, after clicking
on Discard preserved cache.
Not available
125130 Encrypted VDs Physical disks, that were part of an encrypted virtual
disk that has been deleted, still show ‘Encrypted’
property as ‘Yes.
Not available
136314 NVMe device
protocol
The NVMe device protocol for Intel NVMe P4800x
devices is displayed as NVMe 1.1 instead of NVMe 1.0
on supported Linux distros .
Not available
147761 Blink and unblink
operation is blocked
for HHHL add-in
card
Blink and unblink operation under virtual disk tasks in
software RAID is blocked, if any of the participating
physical disk is HHHL add- in card. Blink and unblink
operation is also blocked for Non Raid HHHL add in card
virtual disk.
Not available
149079 OMSS component
versions
Storage Management Component's versions running
on Ubuntu operating system will be shown as
9.4.0 whereas for other systems running on Linux
operating systems like RHEL or SLES version will be
displayed as 6.4.0 in software summary page of Server
Administrator.
Not available
Not available Physical device part
number
On BOSS controller, the failed alert for the physical
drive part number will be displayed as NULL.
Not available
125128 Import SEKM
encrypted VD
Importing an SEKM Encrypted virtual disk on a normal
or non-SEKM setup, displays a blank page on Foreign
Configuration Wizard.
Not available
Not available PDR events On PERC and HBA controllers PDR16, PDR51, PDR7
and PDR22 events are generated once in 24 hours.
Not available
Not available PDR events On PERC and HBA Controller use a single event PDR16
for the events PDR16 and PDR19.
Not available
151771 Multiple partial
spanned RAID-10
On Software RAID controllers, while creation of multiple
partial spanned RAID-10 virtual disks, the physical disks
Not available
23