Release Notes

Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
104973 Enhanced mode On enhanced mode, an alert is displayed as A Device is
inserted in the enclosure for both Power unit and FAN
inserted into enclosure. The message does not state the
specific device inserted.
Not available
103150 Storage tree does
not display the
Enclosure ID
On PowerEdge R940XA with dual backplane, the
Storage tree does not display the Enclosure ID
intermittently during insertion or removal of multiple
drives.
Restart the Data-Manager
service to resolve this
discrepancy.
94890 Fully populated
chassis
For fully populated chassis, the Storage Management
system takes few minutes to load the storage
components.
Not available
95176 Intelligent mirror
VDs
The Physical disks available in MX5016s connected to
chassis slot 8 does not support RAID-10 intelligent
mirror virtual disk creation.
Not available
101739 EMM failure alerts If an EMM is removed from MX5016s sled, EMM failure
or removal alert is not observed on Server Administrator
alerts.
Not available
109008,
192253,
198228
Backplane
enumeration
On a server with multiple independent backplane type
such as SATA, PCIe, or Universal, when a software
RAID or PCIe SSD subsystem controller is connected
to one of the backplanes, there will be an invalid entry
of an enclosure backplane enumerated in OMSS.
No operations and physical disks are enumerated for
the invalid backplane.
The blink/unblink operation might fail for physical disks
and virtual disks on the backplane enumerated under
software RAID controller.
Not available
98675 Hot-plugged
devices
On Server Administrator page, a delay is observed on
hot-pluggable devices when hot-plugged in or out on
HBA 330 MMZ.
Not available
110132,
194288
Enclosure hot-plug When the enclosure is hot plug-in to the 12GBPS HBA
controller observes an additional physical disk id in alert
log page.
Not available
112768 Intel NVMe P4800x
devices
On systems running SUSE Linux Enterprise 15.0
operating system the device protocol of Intel NVMe
P4800x devices display NVMe 0.0 instead of NVMe 1.0.
Not available
111625, 112746 Create or delete
VDs on systems
running ESXi
In a maximum configuration setup i.e. eight enclosures
connected to PERC H840 controller, performing
creating or deleting virtual disk operation multiple times
with more than 160 plus physical drives on systems
running ESXi. 168698We observe core or virtual disk
creation failure.
Restart sfcbd service.
108887 XML data
generated
On Storage Management, observes intermittently
malformed alert log showing XML Data generated for
the selection made is not well formed on systems
running ESXi operating system.
Clear logs and restart the
service.
119082 Multipath mode On multipath mode, if clear redundant path option is
performed immediately after removing the enclosure
cable, few minutes of delay is observed on Server
Administrator UI to refresh.
Not available
22