Release Notes
Table Of Contents
- Dell EMC OpenManage Server Administrator Release Notes Version 10.1.0.0
- Product description
- OMSA Customer Survey
- Platforms Affected
- Requirements
- What is new in this release
- Installation Procedure
- Known issues and workarounds for Server Administrator
- User notes
- Storage Management Service
- Installation Prerequisites
- Known issues and workarounds for Storage Management Service
- User notes for Storage Management Service
- List of firmware for PERC controllers
- List of firmware for BOSS controllers
- Microsoft Windows Drivers for PERC and BOSS Controllers
- Linux and VMware ESXi Drivers for PERC and BOSS Controllers
- Copyright
Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
on systems running the ESXi 5.1 or later operating
system.
8321
(BITS220411)
Secure virtual disk Unable to create Partial Secure virtual disk using the
GUI when all the available SEDs are selected.
This operation will work if any
other physical disk, which is
not a part of any virtual disk,
is connected.
11205
(BITS242664)
Status of Partial
virtual disk
When a physical disk, which is a part of multiple partial
virtual disks, is reinserted into the system, the status
of the partial virtual disks will be displayed on Storage
Management after a short delay.
Not available
8442
(BITS221272),
13988
(BITS257114)
Enclosure alerts Few enclosure alerts such as Enclosure power on/off
and Fan removal, does not appear if the enclosure is
connected to the server using a SAS 12 Gbps HBA card.
Restart Data-Manager service
to update component status.
10933
(BITS240247)
Displaying the
device name
Storage Management does not display the Device name
on a system where there more than 300 virtual disks.
Not available
16919
(BITS270856)
Precision 7910 On Precision 7910 running a client operating system
(for example, Windows 8.1 x64), the PERC 9.3 driver
version is displayed as outdated and a yellow bang is
shown on such hardware configurations. This issue does
not cause any functionality limitation.
Not available
43557 Slot occupancy
report
In Split Mode, Slot occupancy report displays inaccurate
empty slots when there are no drives connected to the
backplane. The report shows the message empty slots
interchanged between controller. This issue occurs for
the server with no drives attached to the backplane in
split mode only. Slot occupancy report works fine as
expected for servers with a minimum of one drive.
Not available
52091 Cryptographic
erase operation
Cryptographic erase operation might take longer time
to be visible in the drop-down list for the ISE Capable
SATA SSDs after this operation is complete.
Not available
58147 BOSS-S1 controller In the BOSS-S1 controller properties, slot ID is displayed
as "Embedded".
Not available
Not available Prepare to Remove If the background IO is in progress, "Prepare to
Remove" operation for the NVME devices might fail.
Not available
Not available Channel/Connector
information
From YX4X onwards, no Channel/Connector
information will be displayed under “PCIe SSD
Subsystem”. Enclosure/Backplane will be directly
connected to the “PCIe SSD Subsystem”. There is no
change in the display of “NVMe Devices ( Arraydisk )
and Add-On Card ( HHHL Card )”. NVMe Devices
( Arraydisk ) will be displayed under “Enclosure /
Backplane” whereas Add-On Card ( HHHL Card ) will
be displayed under “PCIe SSD Subsystem”.
Not available
71918 SAS controllers On YX4X generation of PowerEdge servers when
connected with two SAS 12Gbps controllers in Slot
4 & Slot 5 and each controllers are connected with
separate MD1400 enclosure, both Enclosure EMMs are
listed under “Connector 0” and no device is listed
under “Connector 1 ”. Slot-4 SAS 12Gbps controller is
connected with two redundant EMMs which are listed
in “Connector 0”. Slot-5 12 Gbps controller is also
Not available
20