Table 6. Known issues for Storage Management Service (continued)
Issue ID Functional area Description Workaround/Resolutions
Management tab > SNMP Traps subtab. The SNMP
Traps subtab has options for enabling and disabling
SNMP traps based on severity or the component that
generates the trap. Even when the SNMP traps are
disabled, Storage Management generates SNMP traps.
Not available omconfig storage When issuing certain omconfig storage CLI commands
with Power User privileges, the Error! User has
insufficient privileges to run command: omconfig
message may be displayed.
You must be logged in as an
Administrator to perform these
actions.
Not available Advanced Create
Virtual Disk
Using the Storage Management Service Advanced
Create Virtual Disk Wizard may occasionally result
in a vertical scrollbar of less than normal width. If
this occurs, resizing the Server Administrator window
causes the vertical scrollbar to be redrawn correctly.
Not available
Not available Rename virtual disk Using the GUI, if a virtual disk is renamed to a name
containing multiple blank and consecutive spaces, the
name is truncated to a single space after Apply is
clicked.
Not available
BITS118226 NVMe devices The representation of NVMe devices residing on
backplanes that attach to PCIe Extender cards is
inaccurate on Storage Management. This is because
Storage Management does not have a process
to understand the mapping of the NVMe device,
backplane, and the PCIe Extender card. This issue
exists only on PowerEdge R920 servers and does
not impact the operations on the NVMe device.
Multiple backplanes on Server Administrator indicate
the presence of multiple PCIe Extender cards on the
system.
Not available
Not available Configuration of
enclosures
On a PowerEdge server with maximum configuration
of 8 populated enclosures connected to the PERC
hardware controller, the user can experience a delay
in response. When Server Administrator storage
commands such as Create Virtual Disk or Start check
consistency are run, the delay in response can range
from 10 — 30 minutes.
Not available
Not available Mock backplane On PowerEdge T430, C4130, and R220 II, with
PERC S130 configuration and no backplane, Storage
Management displays a mock backplane which does not
support the blink/unblink operation for disks available
on this configuration.
Not available
BITS140465 Virtual disk of RAID When the user tries to create another partial virtual
disk of any RAID level, on an existing, but degraded
disk group, Storage Management does not allow the
user to perform this action. This limitation occurs
because Storage Management does not support this
functionality. However, this limitation is only observed
on certain PERC 9 family of hardware controllers
(PERC H330, H830, and H730).
The user can create a partial
virtual disk during system
restart using the CTRL+R
configuration utility.
10452
(BITS236815)
PERC 9 Occasionally, the virtual disk creation process on PERC
9 hardware controllers may fail on GUI and CLI.
Workaround: Restart the server to resolve this issue.
Not available
BITS055347 VMware ESXi 5.1 On systems running the ESXi 5.1 or later operating
system, the “Device Name” for all virtual disks will be
displayed as Not Available. This is an expected behavior
Not available
19