SNMP Trap
Numbers
1151
Event ID 2178
Description The controller battery Learn cycle has timed out.
Severity Warning / Non-critical
Cause and Action Cause: The controller battery must be fully charged before the Learn cycle can begin. The battery may
be unable to maintain a full charge causing the Learn cycle to timeout. Additionally, the battery must be
able to maintain cached data for a specified period of time in the event of a power loss. For example,
some batteries maintain cached data for 24 hours. If the battery is unable to maintain cached data for the
required period of time, then the Learn cycle timeout occurs.
Action: Replace the battery pack as the battery is unable to maintain a full charge.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID 2179
Description
The controller battery Learn cycle has been postponed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2180
Description
The controller battery Learn cycle starts in % 1 days.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes. The %1 indicates a substitution variable. The text for this
substitution variable is displayed with the alert in the alert log and can vary depending on the situation.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
98 Storage Management Message Reference