Severity Warning / Non-critical
Cause and Action Cause: The battery may be recharging, the room temperature may be too hot, or the fan in the system
may be degraded or failed.
Action: If this alert was generated due to a battery recharge, the situation is corrected when the
recharge is complete. You should also check if the room temperature is normal and that the system
components are functioning properly.
Related Alert
Information
Clear Alert Number: 2172
Related Alert Number: None
Local Response Agent (LRA) Number: 2100
SNMP Trap
Numbers
1153
Event ID 2172
Description The controller battery temperature is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2172 is a clear alert for alert 2171.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2173
Description
Unsupported configuration detected. The SCSI rates of the enclosure management modules (EMMs) are
not the same. EMM 0 % 1 EMM 1 % 2
Severity Warning / Non-critical
Cause and Action Cause: An unsupported configuration was detected.
Action: Replace one of the EMMs with the matching SCSI rate EMM.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2090
SNMP Trap
Numbers
853
Event ID 2174
Description
The controller battery has been removed.
Severity Warning / Non-critical
Cause and Action Cause: The controller cannot communicate with the battery. The battery may be removed, or the contact
point between the controller and the battery may be burnt or corroded.
96 Storage Management Message Reference