Reference Guide

Table Of Contents
Event ID 2168
Description The non-RAID SCSI driver version is older than the minimum required level. See readme.txt for the
validated driver version.
Severity Warning / Non-critical
Cause and Action Cause: The version of the driver does not meet the minimum requirements. Storage Management may
not be able to display the storage or perform storage management functions until you have updated the
system to meet the minimum requirements.
Action: See the Readme file for the validated driver version. Update the system to meet the minimum
requirements and then reinstall Storage Management.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2050
SNMP Trap
Numbers
103
Event ID 2169
Description The controller battery needs to be replaced.
Severity Critical / Failure / Error
Cause and Action Cause: The controller battery cannot be recharged. The battery may be old or it may have been already
recharged the maximum number of times. In addition, the battery charger may not be working.
Action: Replace the battery pack.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2118
Local Response Agent (LRA) Number: 2101
SNMP Trap
Numbers
1154
Event ID 2170
Description
The controller battery charge level is normal.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2171
Description
The controller battery temperature is above normal.
Storage Management Message Reference 95