Event ID 2162
Description Communication regained.
Severity OK / Normal / Informational
Cause and Action Cause: Communication with an enclosure has been restored. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2162 is a clear alert for alerts 2137 and 2292.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
851
Event ID 2163
Description Rebuild completed with errors.
Severity OK / Normal / Informational
Cause and Action Cause: During a rebuild one or more blocks of data was not recoverable due to missing parity information.
Some data loss may have occurred.
Action: Perform a check to verify the built array. Any files that are impacted should be restored from a
backup. See the Storage Management online help for more information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID 2164
Description
See the Readme file for a list of validated controller driver versions.
Severity OK / Normal / Informational
Cause and Action Cause: Storage Management is unable to determine whether the system has the minimum required
versions of the RAID controller drivers. This alert is for informational purposes.
Action: See the Readme file for driver and firmware requirements. In particular, if Storage Management
experiences performance problems, you should verify that you have the minimum supported versions of
the drivers and firmware installed.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
101
Event ID 2165
Description
The RAID controller firmware and driver validation was not performed. The configuration file cannot be
opened.