Reference Guide

Table Of Contents
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a
nonredundant virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes
the virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2111
Description Failure prediction threshold exceeded due to test.
Severity Warning / Non-critical
Cause and Action Cause: A disk has received a SMART alert (predictive failure) due to test conditions.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2112
Description
Enclosure was shut down.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is either hotter or cooler than the maximum or minimum allowable
temperature range.
Action: Check for factors that may cause overheating or excessive cooling. For example, verify that
the enclosure fan is working. You should also check the thermostat settings and examine whether the
enclosure is located near a heat source. Make sure the enclosure has enough ventilation and that the
room temperature is not too hot or too cold. See the enclosure documentation for more diagnostic
information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
854
Event ID 2114
Description
A consistency check on a virtual disk has been paused (suspended).
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation on a virtual disk was paused by a user.
78 Storage Management Message Reference