Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2105 is a clear alert for alert 2104.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2106
Description SMART FPT exceeded.
Severity Warning
Cause and Action Cause: A disk on the specified controller has received a SMART alert (predictive failure) indicating that
the disk is likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a
non-redundant virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes
the virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2107
Description
SMART configuration change.
Severity Critical / Failure / Error
Cause and Action Cause: A disk has received a SMART alert (predictive failure) after a configuration change. The disk is
likely to fail in the near future.
Action: Replace the disk that has received the SMART alert. If the physical disk is a member of a
non-redundant virtual disk, then back up the data before replacing the disk.
CAUTION: Removing a physical disk that is included in a non-redundant virtual disk causes
the virtual disk to fail and may cause data loss.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
76 Storage Management Message Reference