Reference Guide

Table Of Contents
Event ID 2102
Description Temperature exceeded the maximum failure threshold.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is too hot. A variety of factors can cause the excessive temperature.
For example, a fan may have failed, the thermostat may be set too high, or the room temperature may be
too hot.
Action: Check for factors that may cause overheating. For example, verify that the enclosure fan is
working. You should also check the thermostat settings and examine whether the enclosure is located
near a heat source. Make sure the enclosure has enough ventilation and that the room temperature is not
too hot. See the physical disk enclosure documentation for more diagnostic information.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1054
Event ID 2103
Description Temperature dropped below the minimum failure threshold.
Severity Critical / Failure / Error
Cause and Action Cause: The physical disk enclosure is too cool.
Action: Check if the thermostat setting is too low and if the room temperature is too cool.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2112
Local Response Agent (LRA) Number: 2091
SNMP Trap
Numbers
1054
Event ID 2104
Description
Controller battery is reconditioning.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: 2105
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1151
Event ID 2105
Description
Controller battery recondition is completed.
Storage Management Message Reference 75