Reference Guide

Table Of Contents
Action: Replace the physical disk. Even though the disk may not have failed yet, it is strongly
recommended that you replace the disk.
If this disk is part of a redundant virtual disk, perform the Offline task on the disk; replace the disk; the
rebuild starts automatically.
NOTE: If you put the drive in a different slot, you need to assign it as a hot spare for the rebuild to
start automatically.
If this disk is a hot spare, then unassign the hot spare; perform the Prepare to Remove task on the disk;
replace the disk; and assign the new disk as a hot spare.
CAUTION: If this disk is part of a non-redundant disk, back up your data immediately. If the
disk fails, you cannot recover the data.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Part Number= <Part Number>
Local Response Agent (LRA) Number: 2070
SNMP Trap
Numbers
903
Event ID 2095
Description
SCSI sense data %1.
Severity OK / Normal / Informational
Cause and Action Cause: A SCSI device experienced an error, but may have recovered.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2273
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
751, 851, 901
Event ID 2098
Description
Global hot spare assigned.
Severity OK / Normal / Informational
Cause and Action Cause: A user has assigned a physical disk as a global hot spare. This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2277
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Event ID 2099
Description
Global hot spare unassigned.
Storage Management Message Reference 73