Reference Guide

Table Of Contents
Event ID 2082
Description Virtual disk rebuild failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have
cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the
disk that has a red X for its status. Restart the virtual disk rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2081
SNMP Trap
Numbers
1204
Event ID 2083
Description Physical disk rebuild failed.
Severity Critical / Failure / Error
Cause and Action Cause: A physical disk included in the virtual disk has failed or is not functioning. A user may also have
cancelled the rebuild.
Action: Replace the failed or non-functional disk. You can identify a disk that has failed by locating the
disk that has a red X for its status. Rebuild the virtual disk rebuild.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap
Numbers
904
Event ID 2085
Description
Virtual disk check consistency completed.
Severity OK / Normal / Informational
Cause and Action Cause: This alert is for informational purposes.
Action: None
Related Alert
Information
Clear Alert Number: Alert 2085 is a clear alert for alert 2058.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2086
Description
Virtual disk format completed.
Severity OK / Normal / Informational
70 Storage Management Message Reference