Reference Guide

Table Of Contents
SNMP Trap
Numbers
901
Event ID 2067
Description Virtual disk check consistency cancelled.
Severity OK / Normal / Informational
Cause and Action Cause: The check consistency operation was cancelled because a physical disk in the array has failed or
because a user cancelled the check consistency operation.
Action: If the physical disk failed, then replace the physical disk. You can identify which disk failed
by locating the disk that has a red X for its status. Perform a rescan after replacing the disk. The
consistency check can take a long time. The time it takes depends on the size of the physical disk or the
virtual disk.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2070
Description
Virtual disk initialization cancelled.
Severity OK / Normal / Informational
Cause and Action Cause: The virtual disk initialization cancelled because a physical disk included in the virtual disk has failed
or because a user cancelled the virtual disk initialization.
Action: If a physical disk failed, then replace the physical disk. You can identify which disk has failed by
locating the disk that has a red X for its status. Perform a rescan after replacing the disk. Restart the
format physical disk operation. Restart the virtual disk initialization.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
1201
Event ID 2074
Description
Physical disk rebuild cancelled.
Severity OK / Normal / Informational
Cause and Action Cause: The user has cancelled the rebuild operation.
Action: Restart the rebuild operation.
Related Alert
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
901
Storage Management Message Reference 67