Reference Guide

Table Of Contents
Table 4. Message Format with Variables for Each Storage Object (continued)
Storage Object Message Variables
For example, 2121 Device returned to normal: Fan 1, Controller 1, Connector 0, Target ID 6
SAS Fan
Message Format: Fan X Controller A, Connector B, Enclosure C
For example, 2121 Device returned to normal: Fan 1, Controller 1, Connector 0, Enclosure 2
SCSI EMM
Message Format: EMM X Controller A, Connector B, Target ID C
where C is the SCSI ID number of the EMM.
For example, 2121 Device returned to normal: EMM 1, Controller 1, Connector 0, Target ID 6
SAS EMM
Message Format: EMM X Controller A, Connector B, Enclosure C
For example, 2121 Device returned to normal: EMM 1, Controller 1, Connector 0, Enclosure 2
Alert Descriptions and Corrective Actions
The following sections describe alerts generated by the RAID or SCSI controllers supported by Storage Management. The alerts
are displayed in the Server Administrator Alert tab or through Windows Event Viewer. These alerts can also be forwarded as
SNMP traps to other applications.
SNMP traps are generated for the alerts listed in the following sections. These traps are included in the Server Administrator
Storage Management, management information base (MIB). The SNMP traps for these alerts use all of the SNMP trap
variables. For more information on SNMP support and the MIB, see the SNMP Reference Guide.
To locate an alert, scroll through the following table to find the alert number displayed on the Server Administrator Alert tab
or search this file for the alert message text or number. See Understanding Event Messages for more information on severity
levels.
For more information regarding alert descriptions and the appropriate corrective actions, see the online help.
Event ID 2048
Description
Device failed.
Severity Critical / Failure / Error
Cause and Action Cause: A storage component such as a physical disk or an enclosure has failed. The failed component
may have been identified by the controller while performing a task such as a rescan or a check
consistency.
Action: Replace the failed component. You can identify which disk has failed by locating the disk that has
a red X for its status. Perform a rescan after replacing the failed component.
Related Alert
Information
Clear Alert Number: 2121
Related Alert Number: 2095, 2201, 2203
Local Response Agent (LRA) Number: 2051, 2061, 2071, 2081, 2091, 2101
SNMP Trap
Numbers
754, 804, 854, 904, 954, 1004, 1054, 1104, 1154, 1204
Event ID 2049
Description
Physical disk removed.
Severity Warning / Non-critical
Cause and Action Cause: A physical disk has been removed from the disk group. This alert can also be caused by loose or
defective cables or by problems with the enclosure.
Storage Management Message Reference 61